ESD and Static Control, Protection, Supplies and Products
|
|
|
|
|
|
|
|
|
| Wrist Straps & Coil Cords |
|
|
|
| Worksurface Mats and Grounding Hardware |
|
| Floor Mats and Grounding Hardware |
|
| Floor Finish, Paint, and Epoxy |
|
|
| Monitors, Testers and Measurement |
|
|
| Education, Awareness, and Accessories |
|
|
|
|
|
|

Additional Images:
1
|
17273 - FOOT GROUNDER, FULL COVERAGE, NON-MARRING, XLARGE
|
You must be logged in
to purchase from
our online catalog.
Signup
or Login above.
|
|
|
| Fax / Email List Price |
Internet List Pricing |
|
|
|
|
|
| Drawings |
|
17270
-
Full Coverage Non-Marring Foot Grounder
|
|
- Unique Design Requires No Fastening System
Flexible material that stretches over most shoes for quick and easy installation
- Contact Points on Foot’s Sole and Heel Area
Charge generation is generally lower than conventional heel straps due to the continuous path to ground throughout walking motion. Click here for full report from Affinity Static Control Consulting LLC.
- Neoprene Rubber With No Exposed Carbon
Will not mar shoes or floors - reducing maintenance costs of touching up on floors
- 18" Long, 8 Conductive Strand Nylon Polyester Grounding Tab
Additional conductive material provides reliable connection with operator’s sweat-layer
- One Megohm Series Resistor
To protect operator from accidental contact with equipment line voltage
- UL Listed
Independently reviewed for adequacy of the product's design
- Date Coded
Provides lot traceability to ensure quality control and tracking information
- Made In The United States of America
This item is made in Rochester, NH and stocked in Canton, MA
Estimated Shipping Weight: 0.084 Pounds Per ESD SP9.2 APPENDIX B - Foot Grounder Usage Guidance “Compliance verification should be performed prior to each use (daily, shift change, etc.). The accumulation of insulative materials may increase the foot grounder system resistance. If foot grounders are worn outside the ESD protected area testing for functionality before reentry to the ESD protected area should be considered.”
Per ANSI/ESD S20.20 Paragraph 6.2.2.2 Personnel Grounding Guidance, “ESD protective flooring, used with approved footwear, may be used as an alternative to the wrist strap system for standing operations.”
ESD Handbook TR 20.20 paragraph 5.2.3 “If the contact area between the bottom of the foot and the floor is not continuous, charge generation may occur especially when a person is walking. Heel straps must be worn on both feet to minimize the amount of time that the body of the person is isolated from ground while walking.”
Suitable for ESD footwear component in Flooring - Footwear System personnel grounding method (<3.5 x 10E7 ohms per ESD STM 97.1). Suitable for ESD footwear component in flooring - Footwear System personnel grounding method (<100 volts per ESD STM 97.2).
|
|
|
Additional Information |
|
|
Click here for a Selection Chart of all Desco Foot Grounders. Click here for proper installation instructions of Desco Full Coverage Foot Grounders. Click here for sizing information. Click here for full report on low charge generation.
|
|
|
|
|
|