My Account Catalog Resources Reps & Dist. Help Desk

Other Desco
Industries Brands
Phone: (909) 627-8178

Full Catalog > Testing and Measurement Equipment > Continuous Monitors > Dual Wire Continuous Monitors >




19665 - MONITOR, DUAL WIRE CONTINUOUS 10/35M, SE900,120V
You must be logged in
to purchase from
our online catalog.
Signup or Login above.
Quantity in Stock: 52
Quantity Price Breaks

1
$253.88

 
  • Dual Station Continuous Monitor For 2 Operators And 2 Work Surfaces
    Continuously monitors the integrity of both operators and ESD workstations, eliminating the need for periodic testing and recording.
  • Patented Low Voltage Steady State Dc Continuous Loop Monitoring Technology
    True continuous monitoring (versus pulsed or intermittent) of dual wire wrist strap functionality and operator safety according to accepted industry standards.
  • Two Independent Operator Wrist Strap Ground Point Remotes With 10’ Cables.
    Ideal for adjacent workstations for assembly, test, packaging, or other applications.
  • Independent Alarming Conditions: Audible And Visual
    LED display and audible alarm makes it easy to monitor the status of the work surfaces and operators.
  • Stainless Steel Housing
    Minimizes foreign objects debris, corrosion, and other contamination when used in clean or sensitive areas.
  • Test for Proper Calibration with the Desco EMIT 50524 Dual-Wire Monitor Limit Comparator
  • Made in America

Dual Wire Continuous Monitors provide redundancy; even if one dual wire wrist strap conductor is severed, operator has reliable path-to-ground with other wire. To see Desco’s selection of dual wire wrist straps Click Here

ESD Handbook TR 20.20 paragraph 5.3.2.4.4 Test Frequency "Because wrist straps have a finite life, it is important to develop a test frequency that will guarantee integrity of the system. Typical test programs recommend that wrist straps that are used daily should be tested daily. However, if the products that are being produced are of such value that knowledge of a continuous, reliable ground is needed, and then continuous monitoring should be considered or even required"
Per ESD-S1.1 paragraph 6.1.3 Frequency of Functional Testing "Daily [Wrist Strap] testing may be omitted if constant monitoring is used."

Note: Work surface must have a conductive layer such as Dual Layer Rubber or Dissipative 3-Layer Vinyl or Micastat® Dissipative Laminate with conductive buried layers. Desco Continuous Monitors are not recommended for use with homogeneous matting.

Use with Desco mats Statfree T2™, Statfree Z2™, Statfree O™, and Statfree UC™




Technical Documents
TB-3019 - Dual-Wire Workstation Continuous Monitor