09031-CLASP REPLACEMENT FOR 09028

09031-CLASP REPLACEMENT FOR 09028              

09031 - Replacement Clasp for 09028

Internet List Price Fax / Email List Price
Qty: 1 $6.29
Qty: 1 $6.92

In-stock orders will ship in 3 business days or less after receipt of order.

36 Available.

Other Quantities - Contact Us.

Stock Location: CHINO, CA, 3661 WALNUT AVENUE

Country Of Origin: USA

Sold Per: EA

Gross Weight2: 0.02 lb

2The weight listed is gross product weight including standard packaging, actual shipment weight may vary.

Quantity:


 





Bookmark and Share

 

  • Locking clasp
    Band locked so it will not slip
  • Medical grade 300 series stainless steel used for all metal parts
    Eliminates allergic skin reactions for most people
  • Date coded
    Providing lot traceability to ensure quality control
  • Made in the United States of America

Circumference - 2.5" - 13"  
NOTE: All bands have a 4mm snap stud. Complete wrist strap kits include an alligator clip. Wrist strap kits include an alligator clip for occasions when a grounded banana jack is not available. However, best industry practice is that ESD Ground Connections should be firm fitting connecting devices such as metallic crimps, snaps and banana plugs to be connected to designated ground points. Use of alligator clips is not recommended. (Ref: JEDEC Standard No. 625-A)

ANSI/ESD S20.20 Paragraph 6.2.2.1 Personnel Grounding Requirement "All personnel shall be bonded or electrically connected to ground or contrived ground when handling ESD sensitive items. When personnel are seated at ESD protective workstations, they shall be connected to the common point via a wrist strap system."

Reliable Path-to-Ground: Are You Wasting the Money Spent on ESD Control? How Many Accidental Disconnects Occur a Day at Your Plant Putting Your Products at Risk? Read the Evaluation Engineering Magazine Article, "Solving the Wristband Snap Release Problem"
*Reproduced with Permission,
EE-Evaluation Engineering, June, 2001

 

Show more details...
Hide details...
  • Wrist Straps Grounding - Testing and Maintenance
  • TB-2005 - Wrist Straps Grounding - Testing and Maintenance
  • 09028 -
    Adjustable Elastic Wristband
  • 09028 - Adjustable Elastic Wristband
What the ESD Association says about wrist straps:
"Note: Metal expansion bracelet style wrist cuffs may trap moisture underneath and can be more effective for people with dry skin." [ESD Handbook TR20.20 section 5.3.2.4.3]

Per ESD Handbook TR20.20 section 5.3.9.1 Wrist Strap Checkers - “Wrist strap checkers have historically been the primary tool for testing the operation of the wrist strap system including, the wristband, grounding cord and most importantly, the electrical integrity of the contact between the wristband and the wearer. Wrist strap checkers measure the resistance of the entire system.”

NOTE: All bands have a 4mm snap stud. Complete wrist strap kits include an alligator clip. Wrist strap kits include an alligator clip for occasions when a grounded banana jack is not available. However, best industry practice is that ESD Ground Connections should be firm fitting connecting devices such as metallic crimps, snaps and banana plugs to be connected to designated ground points. Use of alligator clips is not recommended. (Ref: JEDEC Standard No. 625-A)

ANSI/ESD S20.20 Paragraph 6.2.2.1 Personnel Grounding Requirement "All personnel shall be bonded or electrically connected to ground or contrived ground when handling ESD sensitive items. When personnel are seated at ESD protective workstations, they shall be connected to the common point via a wrist strap system."

Click here for a Selection Chart on Desco Wrist Straps

Click here to read "Solving the Wristband Snap Release Problem"

For dry skin conditions, see Reztore ESD Hand Lotion