220V AC Outlet Analyzer and Wrist Strap Tester |
|
|||||||||||||||||
|
|
|
||||||||||||||||||
| • 220V UK / Asia outlet analyzer Verifies proper AC outlet wiring and ground path integrity, enabling effectiveness of grounding products • Internal audit tool Tests wrist strap to resistance limits. Tests ESD smock continuity, if it is part of the wrist strap grounding path • Convenient, portable, easy to use Tests wrist strap without leaving workstation • 27 VDC test voltage Minimizes skin resistance effects • Made in America |
|
||||||||||||||||||
|
|
|
![]() |
|
||||||||||||||||
|
|
|
||||||||||||||||||
Note: Per ANSI/ESD S20.20, "In most cases the third wire (green) AC equipment ground is the preferred choice for ground." “The hot, neutral, and equipment grounding conductor shall be verified to be in the proper wiring orientation in accordance with the National Electric Code (Grounding ANSI ESD S6.1 section 6.3.1 Equipment Conductor) “Frequency of Functional Testing: The wrist strap system should be tested daily to ensure proper electrical value. Nominally, the upper resistance reading should be < or = 10 megohms or a user-defined value.” (ANSI/ESD S1.1-2006 Annex A3) |
|
|
|||||||||||||||||
|
|
|